1. ASME B&PV Code Section V Article _________for Liquid Penetrant Testing (Procedure Standard).

A. 6

B. 7

C. 2

D. 8

ANSWER: A. 6

 

2. Standard Practice for Liquid Penetrant Examination for General Industry.

A. ASTM E1316

B. ASTM E709

C. ASTM E165 

D. ASTM E1444

ANSWER: C. ASTM E165 

 

 

3. ASME B&PV Section VIII Div.1 Mandatory Appendix ________.

A. 3

B. 6

C. 7

D. 8

ANSWER: D. 8

 

4. Prior to examination, each adjacent surface shall be cleaned within at least ______inch of the area to be examined. [as per ASME B&PV Section V]

A. 1

B. 1.5

C. 2

D. 3

ANSWER: A. 1

 

5. Which Below Standard is Acceptance Criteria?

A. ASME B&PV Section V

B. ASME B&PV Section VIII Div. 1

C. ASME B&PV Section IX

D. ASTM E 165

ANSWER: B. ASME B&PV Section VIII Div. 1

 

6. What is Linear Indication as per ASME Section VIII Div. 1?

A. L > 3W

B. L =<  3W

C. L > 1.5 mm

D. L =< 1.5 mm

ANSWER: A. L > 3W

 

7. What is Relevant Indication as per ASME Section VIII Div. 1?

A. L > 3W

B. L =<  3W

C. L > 1.5 mm

D. L =< 1.5 mm

ANSWER: C. L > 1.5 mm


8. What is Rounded Indication as per ASME Section VIII Div. 1?

A. L > 3W

B. L =<  3W

C. L > 1.5 mm

D. L =< 1.5 mm

ANSWER: B. L =<  3W

 

 

9. What is Non Relevant Indication as per ASME Section VIII Div. 1?

A. L > 3W

B. L =<  3W

C. L > 1.5 mm

D. L =< 1.5 mm

ANSWER: D. L =< 1.5 mm

 

10. When using fluorescent penetrant, the examiner shall be in a darkened area for at least ____minutes prior to performing the examination.

A. 7

B. 10

C. 9

D. 5

ANSWER: D. 5

 

11.________________or more relevant rounded indications in a line separated by 1.5 mm or less (edge to edge).

[as per ASME B&PV Section VIII Div. 1 – Acceptance Criteria]

A. 2

B. 3

C. 4

D. 5

ANSWER: C. 4

 

12. What is the minimum light intensity when conducting a visible Liquid Penetrant Test?

A. 100 Lx

B. 1000 μW/cm2

C. 1000 Lx

D. 10000 Lx

ANSWER: C. 1000 Lx

 

13. 1 Ftc = _______ Lux

A. 10.78

B. 10.76

C. 10.67

D. 10.87

ANSWER: B. 10.76

 

14. Penetrant is to be applied to a part. What temperature should this be?

A. 125°F Max

B. 125°C Max

C. 130°F is acceptable

D. 30° maximum

ANSWER: A. 125°F Max


15. Water washable penetrant shall be removed with a water spray not exceeding _____ and _____.

A. 150 psi, 200°F

B. 60 psi, 110°F

C. 50 psi, 110°F

D. 50 KSI, 110°F

ANSWER: C. 50 psi, 110°F

 

16. The maximum emulsification time shall be:

A. 5 min.

B. 10 min

C. 15 min.

D. none of the above

ANSWER: D. none of the above

 

17. When should a Lux meter be calibrated as a minimum?

A. Annually

B. Every 90 days

C. Whenever it is turned on

D. As required by the Examiner

ANSWER: A. Annually

 

18. When developing a detailed procedure which of the following should not be considered?

A. Instrument manufacture

B. personnel

C. calibration records

D. objects to be measured

ANSWER: A. Instrument manufacture

 

19. One of the procedural requirements for conducting PT is to address the processing details for_______________.

A. Post-examination cleaning

B. Pre-examination cleaning

C. Apply the penetrant

D. All of the above

ANSWER: D. All of the above

 

20. The determination of whether indications are Relevant, Nonrelevant, or False.

A. Interpretation

B. Evaluation

C. Examination

D. Test

ANSWER: A. Interpretation