Question: What are the different names of liquid penetrant testing?

Answer: Dye Penetrant Testing (DPT), Penetrant Testing (PT), Dye Penetrant Inspection (DPI), Dye Penetrant Inspection (LPI).

 

Question: What is principle of Liquid Penetrant Testing?

Answer: Capillary Action

 

Question: What is Capillary Action?

Answer: Capillary Action is Fluid Flow through a narrow tub or spa from combine effect of Viscosity, Surface Tension, Cohesion and Adhesion.

 

Question: General Liquid Penetrant Testing Steps

Answer:

1)     Precleaning

2)     Penetrant Application

3)     Cleaning (Excess Penetrant removal)

4)     Developer Application

5)     Examination

6)     Post Cleaning

 

Question: What are the types of penetrant as per MIL-I-25135 / AMS 2644?

Answer: The Types of Penetrant are two as per MIL-I-25135 / AMS 2644.

Type 1 - Fluorescent Penetrant Testing

Type 2 - Visible Penetrant Testing

 

Question: What are the Methods of Cleaning as per MIL-I-25135 / AMS 2644?

Answer: The Methods of Cleaning in Liquid Penetrant Testing are Four.

Method A—Water-washable

Method B—Post-emulsifiable, lipophilic

Method C—Solvent removable

Method D—Post-emulsifiable, hydrophilic

 

Question: What are the forms of Developer in LPT as per MIL-I-25135 / AMS 2644?

Answer: The Forms of Developers in LPT as per MIL-I-25135 / AMS 2644 are Six.

Form a: dry powder

Form b: Water Soluble

Form c: Water Suspendible

Form d: Nonaqueous Type I (for Fluorescent)

Form c: Nonaqueous Type  II (for Visible)

form r: Special application


Question: What are the types of Solvents as per AMS 2644?

Answer: Types of Solvent are Three.

Class  1: halogenated

Clsss 2: nonhalogenated

Class  3: special  application

 

Question: What types of defects can be detected in a liquid penetrant test?

Answer: Surface Defects